Texas Eastern Transmission Notice 177496
Source LinkAll information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP: 
TSP Name: 
Critical Notice Description: 
Notice Effective Date: 
Notice Effective Time: 
Notice End Date: 
Notice End Time: 
Notice Identifier: 
Notice Status Description: 
Notice Type: 
Posting Date: 
Posting Time: 
Prior Notice Identifier: 
Required Response
Indicator Description: 
Response Date: 
Response Time: 
Subject: 
TSP Name: 
Critical Notice Description: 
Notice Effective Date: 
Notice Effective Time: 
Notice End Date: 
Notice End Time: 
Notice Identifier: 
Notice Status Description: 
Notice Type: 
Posting Date: 
Posting Time: 
Prior Notice Identifier: 
Required Response
Indicator Description: 
Response Date: 
Response Time: 
Subject: 
007932908
Texas Eastern Transmission, LP
Critical notice
05/05/2026
09:28:29 AM
05/06/2026
09:00:00 AM
177496
Supersede
Capacity Constraint
05/05/2026
09:28:29 AM
177484
No response required
TE Pipeline Conditions for 5/5/2026 -- INTRADAY
Texas Eastern Transmission, LP
Critical notice
05/05/2026
09:28:29 AM
05/06/2026
09:00:00 AM
177496
Supersede
Capacity Constraint
05/05/2026
09:28:29 AM
177484
No response required
TE Pipeline Conditions for 5/5/2026 -- INTRADAY
Notice Text:
| For Gas Day May 5, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity: | ||||||||||
| Restricted Locations | Scheduled and Sealed | Priority % Restricted | Notes | |||||||
| TABS | IT | 4B | 4A | 3 | 2 | 1 | ||||
| North of Berne | ||||||||||
| Meter 75919 Deliveries | N/A | 100% | 100% | 88% | ||||||
| Rec from AGT & Del West of Lambertville | 100% | 100% | 100% | |||||||
| Deliveries to Oakford | N/A | 100% | 100% | 100% | Planned Outage | |||||
| TE/AGT Lease | Yes | To Lease Capacity | ||||||||
| Nexus/TE Leased Meters | Yes | To Lease Capacity | ||||||||
| 30" South of Berne | ||||||||||
| Berne South | Yes | |||||||||
| Athens | N/A | 100% | 100% | 100% | Unplanned Outage | |||||
| Danville | N/A | 100% | 100% | Planned Outage | ||||||
| Tompkinsville | N/A | 100% | 100% | |||||||
| Barton | N/A | 100% | 100% | |||||||
| 24" | ||||||||||
| Sarahsville South | N/A | 100% | 100% | 13% | Planned Outage | |||||
| Five Points South | N/A | 100% | 80% | |||||||
| Lebanon | Yes | |||||||||
| Lebanon Lateral | Yes | |||||||||
| Batesville South | N/A | 100% | 37% | |||||||
| Meter 73581 Receipts | Yes | Planned Outage | ||||||||
| Meter 70215 Receipts | N/A | 100% | 100% | 100% | Planned Outage | |||||
| Meter 74215 Deliveries | N/A | 100% | 100% | 100% | 100% | 100% | 100% | Planned Outage | ||
| Access Area | ||||||||||
| New Roads South | N/A | 100% | 81% | |||||||
| White Castle South | Yes | |||||||||
| Union Church | N/A | 100% | 79% | |||||||
| Longview | N/A | 100% | 49% | |||||||
| Deliveries to the Castor Line | N/A | 100% | 48% | |||||||
| Huntsville | Yes | |||||||||
| Speaks | N/A | 100% | 79% | |||||||
| Angleton West | N/A | 100% | 59% | |||||||
| East Golden Pass | N/A | 100% | 11% | |||||||
| Gillis | N/A | 100% | 57% | |||||||
| TABS Pool Restrictions - Tolerances | ETX | STX | WLA | ELA | M1-24" | M1-30" | M2-24" | M2-30" | M3 | |
| TABS Pool - Length | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | |
| TABS Pool - Short | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | |
| No-Notice Restrictions | ||||||||||
| OFO / Imbalance Notice | ||||||||||
| OFO | No DS - M2-24, M2-30 and M3, issued 5/4/2026. 2% / 250 Dth Tolerance | |||||||||
| Action Alert | --- | |||||||||
| Customer Specific OFO | --- | |||||||||
| Imbalance Warnings | Stay Balanced - Access Area, M1-24 and M1-30 | |||||||||
| FERC Order 698 | M2-24, M2-30 and M3 | |||||||||
| Systemwide Notes: | ||||||||||
| (2) Due to intraday nomination changes. | ||||||||||
| Shippers in Texas Eastern's Access Area Zones and Market Area Zones M1-24 and M1-30 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs. | ||||||||||
| Beginning Gas Day May 2, 2026, TE anticipates restrictions of approximately 0-7% of P1 nominations at Athens. For future gas days TE will continue to monitor system conditions associated with the posted outages along the 30" system. | ||||||||||
| Beginning 9:00 AM CCT May 2, 2026, through 9:00 AM CCT May 6, 2026, excess injections on all ISS-1, FSS-1, SS-1 and SS contracts will be restricted as well as TT16, TT17, TT24 no-notice balancing, no-notice pre-injection and no-notice payback for prior month. | ||||||||||
| Operational advisory for shippers nominating from 79503: TETLP will upper limit to -0- certain activities if shippers (1) have initial nominations originating from 79503 (WLA TABS Pool) for delivery west of EGP at the Timely Cycle and (2) these shippers are consistently reducing these quantities intraday. TE will be reviewing these activities at the Timely Cycle beginning Gas Day January 30, 2026 until further notice. | ||||||||||
| Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice. Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d. | ||||||||||
| If customers/point operators do not manage hourly takes from the system, it will lead to delivery pressures being lower than desired for this area. As a result, TE may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system, including but not limited to, implementation of flow control at specific delivery meter locations. | ||||||||||
| TE may be required to issue hourly OFO's to impose further restrictions in order to maintain the operational integrity of the system. | ||||||||||
| Please contact your Operations Account Representative should you have any questions. | ||||||||||
TSP: 
TSP Name: 
Critical Notice Description: 
Notice Effective Date: 
Notice Effective Time: 
Notice End Date: 
Notice End Time: 
Notice Identifier: 
Notice Status Description: 
Notice Type: 
Posting Date: 
Posting Time: 
Prior Notice Identifier: 
Required Response
Indicator Description: 
Response Date: 
Response Time: 
Subject: 
TSP Name: 
Critical Notice Description: 
Notice Effective Date: 
Notice Effective Time: 
Notice End Date: 
Notice End Time: 
Notice Identifier: 
Notice Status Description: 
Notice Type: 
Posting Date: 
Posting Time: 
Prior Notice Identifier: 
Required Response
Indicator Description: 
Response Date: 
Response Time: 
Subject: 
007932908
Texas Eastern Transmission, LP
Critical notice
05/05/2026
09:28:29 AM
05/06/2026
09:00:00 AM
177496
Supersede
Capacity Constraint
05/05/2026
09:28:29 AM
177484
No response required
TE Pipeline Conditions for 5/5/2026 -- INTRADAY
Texas Eastern Transmission, LP
Critical notice
05/05/2026
09:28:29 AM
05/06/2026
09:00:00 AM
177496
Supersede
Capacity Constraint
05/05/2026
09:28:29 AM
177484
No response required
TE Pipeline Conditions for 5/5/2026 -- INTRADAY
Notice Text:
| For Gas Day May 5, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity: | ||||||||||
| Restricted Locations | Scheduled and Sealed | Priority % Restricted | Notes | |||||||
| TABS | IT | 4B | 4A | 3 | 2 | 1 | ||||
| North of Berne | ||||||||||
| Meter 75919 Deliveries | N/A | 100% | 100% | 88% | ||||||
| Rec from AGT & Del West of Lambertville | 100% | 100% | 100% | |||||||
| Deliveries to Oakford | N/A | 100% | 100% | 100% | Planned Outage | |||||
| TE/AGT Lease | Yes | To Lease Capacity | ||||||||
| Nexus/TE Leased Meters | Yes | To Lease Capacity | ||||||||
| 30" South of Berne | ||||||||||
| Berne South | Yes | |||||||||
| Athens | N/A | 100% | 100% | 100% | Unplanned Outage | |||||
| Danville | N/A | 100% | 100% | Planned Outage | ||||||
| Tompkinsville | N/A | 100% | 100% | |||||||
| Barton | N/A | 100% | 100% | |||||||
| 24" | ||||||||||
| Sarahsville South | N/A | 100% | 100% | 13% | Planned Outage | |||||
| Five Points South | N/A | 100% | 80% | |||||||
| Lebanon | Yes | |||||||||
| Lebanon Lateral | Yes | |||||||||
| Batesville South | N/A | 100% | 37% | |||||||
| Meter 73581 Receipts | Yes | Planned Outage | ||||||||
| Meter 70215 Receipts | N/A | 100% | 100% | 100% | Planned Outage | |||||
| Meter 74215 Deliveries | N/A | 100% | 100% | 100% | 100% | 100% | 100% | Planned Outage | ||
| Access Area | ||||||||||
| New Roads South | N/A | 100% | 81% | |||||||
| White Castle South | Yes | |||||||||
| Union Church | N/A | 100% | 79% | |||||||
| Longview | N/A | 100% | 49% | |||||||
| Deliveries to the Castor Line | N/A | 100% | 48% | |||||||
| Huntsville | Yes | |||||||||
| Speaks | N/A | 100% | 79% | |||||||
| Angleton West | N/A | 100% | 59% | |||||||
| East Golden Pass | N/A | 100% | 11% | |||||||
| Gillis | N/A | 100% | 57% | |||||||
| TABS Pool Restrictions - Tolerances | ETX | STX | WLA | ELA | M1-24" | M1-30" | M2-24" | M2-30" | M3 | |
| TABS Pool - Length | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | |
| TABS Pool - Short | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | 1% or 1,000 | |
| No-Notice Restrictions | ||||||||||
| OFO / Imbalance Notice | ||||||||||
| OFO | No DS - M2-24, M2-30 and M3, issued 5/4/2026. 2% / 250 Dth Tolerance | |||||||||
| Action Alert | --- | |||||||||
| Customer Specific OFO | --- | |||||||||
| Imbalance Warnings | Stay Balanced - Access Area, M1-24 and M1-30 | |||||||||
| FERC Order 698 | M2-24, M2-30 and M3 | |||||||||
| Systemwide Notes: | ||||||||||
| (2) Due to intraday nomination changes. | ||||||||||
| Shippers in Texas Eastern's Access Area Zones and Market Area Zones M1-24 and M1-30 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs. | ||||||||||
| Beginning Gas Day May 2, 2026, TE anticipates restrictions of approximately 0-7% of P1 nominations at Athens. For future gas days TE will continue to monitor system conditions associated with the posted outages along the 30" system. | ||||||||||
| Beginning 9:00 AM CCT May 2, 2026, through 9:00 AM CCT May 6, 2026, excess injections on all ISS-1, FSS-1, SS-1 and SS contracts will be restricted as well as TT16, TT17, TT24 no-notice balancing, no-notice pre-injection and no-notice payback for prior month. | ||||||||||
| Operational advisory for shippers nominating from 79503: TETLP will upper limit to -0- certain activities if shippers (1) have initial nominations originating from 79503 (WLA TABS Pool) for delivery west of EGP at the Timely Cycle and (2) these shippers are consistently reducing these quantities intraday. TE will be reviewing these activities at the Timely Cycle beginning Gas Day January 30, 2026 until further notice. | ||||||||||
| Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice. Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d. | ||||||||||
| If customers/point operators do not manage hourly takes from the system, it will lead to delivery pressures being lower than desired for this area. As a result, TE may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system, including but not limited to, implementation of flow control at specific delivery meter locations. | ||||||||||
| TE may be required to issue hourly OFO's to impose further restrictions in order to maintain the operational integrity of the system. | ||||||||||
| Please contact your Operations Account Representative should you have any questions. | ||||||||||