TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  02/24/2026 3:49:44PM Notice End Date/Time:  02/25/2026 9:00:00am
Post Date/Time:  2/24/2026 3:49:44 PM Notice ID: 399529
Reqrd Rsp:  1 Rsp Date:  02/24/2026
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 02-24-2026 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of Tuesday, February 24, 2026 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 for all areas east of Sta 219 on the 200 Line and on the 300 Line as well as the 500 Line Segments (527, 529, 530, 539, 534, 542, 548, 860) for over-takes from the system or under-deliveries into the system for all Balancing Parties

 

METER RESTRICTIONS

·         Wright Receipt Meter (Pin 412181) - through approx 4% of SIPss increases due to nominations in excess of operational capacity; 176,972 Dths

SEGMENT RESTRICTIONS

·         STA 25 (Segment 125 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 70,796 Dths

·         STA 47 (Segment 143 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 58,572 Dths

·         STA 63 (Segment 163 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 31,141 Dths

·         MLV 509 Muskrat Line (Segment 515 BH) - through approx 73% of IT increases due to nominations in excess of operational capacity; 3,062 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 107,226 Dths

·         MLV 314 East (Segment 314 BH) - through approx 84% of SOP increases due to nominations in excess of operational capacity; 167,892 Dths

·         STA 315 (Segment 315 BH) - through approx 57% of SOP increases due to nominations in excess of operational capacity; 109,241 Dths

·         STA 317 (Segment 317 BH) - through approx 63% of SOP increases due to nominations in excess of operational capacity; 54,810 Dths

·         STA 321 (Segment 321 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 225,141 Dths

·         STA 325 (Segment 324 FH) - through approx 47% of SOP increases due to nominations in excess of operational capacity; 53,205 Dths

·         MLV 330 (Segment 324 FH) - through approx 53% of SOP increases due to nominations in excess of operational capacity; 32,747 Dths

·         STA 219 North (Segment 219 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 11,000 Dths

·         STA 224 (Segment 224 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 131,699 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 27,388 Dths

·         STA 254 (Segment 249 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 90,723 Dths

LINEPACK RESTRICTIONS

Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.

 

 

STORAGE RESTRICTIONS

·         No Authorized Overrun Withdrawal Services under Rate Schedule FS-AO at the following storage fields:

o   Northern MA (460018)

o   Portland MA (460025)

o   Portland PA (460020)

o   Bear Creek PA (460017)

·         Customers who elected swing on storage or storage swing options for balancing (SOS or SSO) may only swing up to their Maximum Daily Withdrawal (MDWQ) until further notice

·         No Authorized Overrun Withdrawal Services under Rate Schedule FS-F at the following storage field:

o   Pine Prairie Virtual (54628)

·         No Interruptible Storage Withdrawal Services under Rate Schedule IS at the following storage fields:

o   Northern MA (460018) IS-MA

o   Bear Creek PA (460017) IS-PA

·         No Loans or Park Withdrawals under Rate Schedule PAL utilizing the PAL-D or PAL-AO services system-wide

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

 

If you have any questions, please contact your Scheduler.

 

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  02/24/2026 3:49:44PM Notice End Date/Time:  02/25/2026 9:00:00am
Post Date/Time:  2/24/2026 3:49:44 PM Notice ID: 399529
Reqrd Rsp:  1 Rsp Date:  02/24/2026
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 02-24-2026 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of Tuesday, February 24, 2026 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 for all areas east of Sta 219 on the 200 Line and on the 300 Line as well as the 500 Line Segments (527, 529, 530, 539, 534, 542, 548, 860) for over-takes from the system or under-deliveries into the system for all Balancing Parties

 

METER RESTRICTIONS

·         Wright Receipt Meter (Pin 412181) - through approx 4% of SIPss increases due to nominations in excess of operational capacity; 176,972 Dths

SEGMENT RESTRICTIONS

·         STA 25 (Segment 125 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 70,796 Dths

·         STA 47 (Segment 143 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 58,572 Dths

·         STA 63 (Segment 163 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 31,141 Dths

·         MLV 509 Muskrat Line (Segment 515 BH) - through approx 73% of IT increases due to nominations in excess of operational capacity; 3,062 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 107,226 Dths

·         MLV 314 East (Segment 314 BH) - through approx 84% of SOP increases due to nominations in excess of operational capacity; 167,892 Dths

·         STA 315 (Segment 315 BH) - through approx 57% of SOP increases due to nominations in excess of operational capacity; 109,241 Dths

·         STA 317 (Segment 317 BH) - through approx 63% of SOP increases due to nominations in excess of operational capacity; 54,810 Dths

·         STA 321 (Segment 321 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 225,141 Dths

·         STA 325 (Segment 324 FH) - through approx 47% of SOP increases due to nominations in excess of operational capacity; 53,205 Dths

·         MLV 330 (Segment 324 FH) - through approx 53% of SOP increases due to nominations in excess of operational capacity; 32,747 Dths

·         STA 219 North (Segment 219 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 11,000 Dths

·         STA 224 (Segment 224 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 131,699 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 27,388 Dths

·         STA 254 (Segment 249 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 90,723 Dths

LINEPACK RESTRICTIONS

Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.

 

 

STORAGE RESTRICTIONS

·         No Authorized Overrun Withdrawal Services under Rate Schedule FS-AO at the following storage fields:

o   Northern MA (460018)

o   Portland MA (460025)

o   Portland PA (460020)

o   Bear Creek PA (460017)

·         Customers who elected swing on storage or storage swing options for balancing (SOS or SSO) may only swing up to their Maximum Daily Withdrawal (MDWQ) until further notice

·         No Authorized Overrun Withdrawal Services under Rate Schedule FS-F at the following storage field:

o   Pine Prairie Virtual (54628)

·         No Interruptible Storage Withdrawal Services under Rate Schedule IS at the following storage fields:

o   Northern MA (460018) IS-MA

o   Bear Creek PA (460017) IS-PA

·         No Loans or Park Withdrawals under Rate Schedule PAL utilizing the PAL-D or PAL-AO services system-wide

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

 